BIWIN X570 PRO 1TB

The BIWIN X570 PRO 1TB is a PCIe 5.0 SSD. In PyNVMe3 testing, the sample showed high random-read performance across multiple stages. Initialization did not complete after two sudden power-loss tests, and anomalies also occurred during firmware-activation reset and several protocol tests.

👎

BIWIN X570 PRO 1TB | Test Report

Test Platform

Item Test configuration
Drive BIWIN X570 PRO 1TB; M.2 2280, PCIe Gen5 ×4
Sample One sample; serial number 2521014901669
Firmware FWX1223A
Platform NUC, Core Ultra 9 285H, 16 GB RAM; Ubuntu 26.04.1, Linux 7.0.0-38
Tools PyNVMe3 26.11; Quarch PPM for power measurement
PCIe Link 32 GT/s ×4
HMB Not enabled

Test Procedure

PyNVMe3 was used to test protocol, performance, power, stress, power cycling, and model reading.

Category Test ID Scope
Protocol and reset TP1 Management, I/O, reset, power management, register and security functions; some tests were skipped or had anomalies.
Low-power states TP2.a Power consumption and read/write response in low-power states.
Performance and power TP2.b Read/write performance, response time and power at different write-workflow checkpoints.
Stress and data verification TP2.c Completed six hours of stress testing and final full-drive verification.
Sudden power loss and recovery TP2.d Two sudden-power-loss runs failed after power-on initialization in cycles 4 and 2 respectively; 100 cycles were not completed.
Normal power cycles TP2.e Completed 100 normal power cycles.
Advertised performance TP2.f Peak sequential and random read/write performance in a small region.
Link speed switching TP2.g Fixed and dynamic link-speed switching under sustained reads.
Model loading TP2.h Read synthetic images of different sizes at various queue counts and queue depths.

Product Radar

Product Radar

This chart shows five aspects of the tested sample. Protocol covers functions related to NVMe and PCIe specifications; performance covers read and write capability; latency concerns response time; power covers electricity consumption; and other includes stress, power cycling and recovery. Each dimension is scored from 1 to 5, with a higher score farther from the center.

Performance Positioning

Performance Positioning

Each black dot places one drive according to two tests. Farther right means higher sequential write speed; higher up means stronger random read performance. The width and height of the rectangle represent longer response times in two workloads. Color represents power consumption during testing: blue is lower and red is higher.

Model Loading Time

This test simulates reading model images from an SSD and compares loading times at different queue counts and queue depths.

Model Loading Time

The four panels show small (4.7 GiB) and large (40 GiB) model images, each with a single queue and multiple queues. Queue depth on the horizontal axis is the number of read requests that each queue can issue at the same time; the vertical axis shows average read time. A lower line means the read completed sooner under those test conditions. Each point summarizes multiple measurements; the vertical bars show the observed range.

Key Issues

ID Test ID Description
X570-01 TP2.d Two sudden power-loss tests failed to complete after power-on initialization in cycles 4 and 2 respectively; subsequent tests encountered initialization errors.
X570-02 TP1.a After firmware was pending activation, a reset caused an admin command timeout and subsequent readiness timeout during initialization.
X570-03 TP1.a Concurrent self-test and rate-limited writes produced 1,620 and 1,615 slow I/Os of about one second in two runs.
X570-04 TP2.b When reading after selecting low-power states PS2 through PS4, average first-read time was approximately 250–253 ms.
X570-05 TP2.b During concurrent sustained sequential writes and mixed I/O, the mixed workload targeted 1,000 IOPS and achieved approximately 378 IOPS.
X570-06 TP1.d Some blocks returned overlapping-range errors during Boot Partition download, and the subsequent commit failed.
X570-07 TP2.g Two negotiation timeouts were recorded during dynamic link-speed switching under sustained reads.
X570-08 TP1.f Running DSM after selecting a non-operational power state produced 22 slow I/Os of about 1.1–1.3 seconds and a worker error; the cause is unknown.
X570-09 TP1.i After the second incorrect-authentication transaction failed in the TCG test, the retry count differed from the test expectation; transaction rollback behavior remains unconfirmed.