Crucial P510 1TB

The Crucial P510 1TB is a PCIe 5.0 SSD. In PyNVMe3 testing, one first read took over 10 seconds among 100 recoveries after sudden power loss. Long responses were also observed during half-drive TRIM and concurrent sequential writes and mixed I/O. Model loading time varied with queue conditions. Results apply to this sample and test conditions.

Crucial P510 1TB | Test Report

Test Platform

Item Test configuration
Drive Crucial P510 1TB (CT1000P510SSD8); M.2 2280, PCIe Gen5 ×4; manufacturer-stated TLC NAND
Sample One sample; serial number 2547E9CDF330
Firmware K1CR5103
Platform NUC, Core Ultra 9 285H, 16 GB RAM; Ubuntu 26.04.1, Linux 7.0.0-34
Tools PyNVMe3 26.11; Quarch PPM for power measurement
PCIe Link 32 GT/s ×4
HMB 64 MB

Test Procedure

PyNVMe3 was used to test protocol, performance, power, stress, power cycling, and model reading.

Category Test ID Scope
Protocol and reset TP1 Applicable management, I/O, HMB, reset, power management, register and security functions; some were skipped according to capability. No valid firmware upgrade evidence was obtained because an upgrade image was unavailable.
Low-power states TP2.a Power consumption and read/write response in low-power states.
Performance and power TP2.b Sequential, random and mixed I/O performance, response time and supply power at different write-workflow checkpoints.
Stress and data verification TP2.c 109 combined stress cycles followed by full-drive readback verification.
Sudden power loss and recovery TP2.d 100 sudden power-loss cycles under random I/O, with recovery timing and data verification.
Normal power cycles TP2.e 100 normal shutdown and power cycles, with recovery-to-access timing.
Advertised performance TP2.f Peak sequential and random read/write performance in a small region.
Link speed switching TP2.g Fixed Gen5 and dynamic Gen2–Gen5 link-speed changes under a read workload.
Model loading TP2.h Read synthetic images of different sizes at various queue counts and queue depths.

Product Radar

Product Radar

This chart shows five aspects of the tested sample. Protocol covers functions related to NVMe and PCIe specifications; performance covers read and write capability; latency concerns response time; power covers electricity consumption; and other includes stress, power cycling and recovery. Each dimension is scored from 1 to 5, with a higher score farther from the center. The latency score is 3, mainly because some commands waited a long time during half-drive TRIM and mixed I/O response and throughput were limited during sustained sequential writes.

Performance Positioning

Performance Positioning

Each black dot places one drive according to two tests. Farther right means higher sequential write speed; higher up means stronger random read performance. The width and height of the rectangle represent longer response times in two workloads. Color represents power consumption during sequential reads: blue is lower and red is higher.

Model Loading Time

This test simulates reading model images from an SSD and compares loading times at different queue counts and queue depths.

Model Loading Time

The four panels show small (4.7 GiB) and large (40 GiB) model images, each with a single queue and multiple queues. Queue depth on the horizontal axis is the number of read requests that each queue can issue at the same time; the vertical axis shows average read time. A lower line means the read completed sooner under those test conditions. Each point summarizes multiple measurements; the vertical bars show the observed range.

Key Issues

ID Test ID Description
P510-01 TP2.d In 100 recoveries after sudden power loss, the first read took 10.099 seconds in one case.
P510-02 TP2.b During the half-drive TRIM test, 99.9% of commands completed within 721.908 ms; the longest took 1.916 seconds.
P510-03 TP2.b During concurrent sustained sequential writes and mixed reads/writes, the mixed workload targeted 1,000 IOPS and achieved approximately 189 IOPS.
P510-04 TP2.h Model loading time was long at single-queue QD1.
P510-05 TP2.g One timeout occurred during controlled link-speed switching.