TEAMGROUP T-FORCE G70 PRO 1TB | Test Report
Test Platform
| Item | Test configuration |
|---|---|
| Drive | TEAMGROUP T-FORCE G70 PRO 1TB (TM8FFH001T); M.2 2280, PCIe Gen4 ×4 |
| Sample | One sample; serial number 112511100250129 |
| Firmware | 030g0P6H |
| Platform | NUC, Core Ultra 9 285H, 16 GB RAM; Ubuntu 26.04.1, Linux 7.0.0-38 |
| Tools | PyNVMe3 26.11; Quarch PPM for power measurement |
| PCIe Link | 16 GT/s ×4 |
| HMB | Not enabled |
Test Procedure
PyNVMe3 was used to test protocol, performance, power, stress, power cycling, and model reading.
| Category | Test ID | Scope |
|---|---|---|
| Protocol and reset | TP1 | Management, I/O, reset, power management, register and security functions; some tests were skipped or had anomalies. |
| Low-power states | TP2.a | Power consumption and read/write response in low-power states. |
| Performance and power | TP2.b | Sequential, random and mixed I/O performance, response time and supply power at different write-workflow checkpoints. |
| Stress and data verification | TP2.c | A six-hour stress test ended after three cycles due to a readback verification warning; final full-drive verification was not performed. |
| Sudden power loss and recovery | TP2.d | Completed 100 sudden power-loss and power-on recovery cycles. |
| Normal power cycles | TP2.e | Completed 100 normal power cycles. |
| Advertised performance | TP2.f | Peak sequential and random read/write performance in a small region. |
| Link speed switching | TP2.g | Fixed and dynamic link-speed switching under sustained reads. |
| Model loading | TP2.h | Read synthetic images of different sizes at various queue counts and queue depths. |
Product Radar

This chart shows five aspects of the tested sample. Protocol covers functions related to NVMe and PCIe specifications; performance covers read and write capability; latency concerns response time; power covers electricity consumption; and other includes stress, power cycling and recovery. Each dimension is scored from 1 to 5, with a higher score farther from the center. Power is scored 3: after a group of tests, power stayed elevated throughout measurement when a low-power state was requested.
Performance Positioning

Each black dot places one drive according to two tests. Farther right means higher sequential write speed; higher up means stronger random read performance. The width and height of the rectangle represent longer response times in two workloads. Color represents power consumption during testing: blue is lower and red is higher.
Model Loading Time
This test simulates reading model images from an SSD and compares loading times at different queue counts and queue depths.

The four panels show small (4.7 GiB) and large (40 GiB) model images, each with a single queue and multiple queues. Queue depth on the horizontal axis is the number of read requests that each queue can issue at the same time; the vertical axis shows average read time. A lower line means the read completed sooner under those test conditions. Each point summarizes multiple measurements; the vertical bars show the observed range.
Key Issues
| ID | Test ID | Description |
|---|---|---|
| G70-01 | TP2.b | After several read/write tests, PS4 was requested and power measured approximately 902–1,008 mW continuously, versus 4.3 mW before testing. Actual power state was not confirmed at every point. |
| G70-02 | TP1.h | After invalid PRP injection, eight cases timed out waiting for completion, followed by ten readiness timeouts during initialization. Later tests continued; the cause is unknown. |
| G70-03 | TP2.c | The planned six-hour stress test ended after three cycles when a readback verification warning occurred in a deallocated region. Final full-drive verification was not performed; persistent data corruption was not confirmed. |
| G70-04 | TP2.g | Thirty negotiation timeouts were recorded while dynamically switching link speed under sustained reads. Gen4 was restored after the test; the cause is unknown. |