TEAMGROUP T-FORCE G70 PRO 1TB

The T-FORCE G70 PRO 1TB is a PCIe 4.0 SSD. PyNVMe3 testing measured about 7.1 GB/s in short-duration sequential reads. Stress testing ended early, and power stayed elevated after low-power state requests following the test flow. Timeouts occurred in invalid-command and link-switching tests. Results apply to this sample and test conditions.

TEAMGROUP T-FORCE G70 PRO 1TB | Test Report

Test Platform

Item Test configuration
Drive TEAMGROUP T-FORCE G70 PRO 1TB (TM8FFH001T); M.2 2280, PCIe Gen4 ×4
Sample One sample; serial number 112511100250129
Firmware 030g0P6H
Platform NUC, Core Ultra 9 285H, 16 GB RAM; Ubuntu 26.04.1, Linux 7.0.0-38
Tools PyNVMe3 26.11; Quarch PPM for power measurement
PCIe Link 16 GT/s ×4
HMB Not enabled

Test Procedure

PyNVMe3 was used to test protocol, performance, power, stress, power cycling, and model reading.

Category Test ID Scope
Protocol and reset TP1 Management, I/O, reset, power management, register and security functions; some tests were skipped or had anomalies.
Low-power states TP2.a Power consumption and read/write response in low-power states.
Performance and power TP2.b Sequential, random and mixed I/O performance, response time and supply power at different write-workflow checkpoints.
Stress and data verification TP2.c A six-hour stress test ended after three cycles due to a readback verification warning; final full-drive verification was not performed.
Sudden power loss and recovery TP2.d Completed 100 sudden power-loss and power-on recovery cycles.
Normal power cycles TP2.e Completed 100 normal power cycles.
Advertised performance TP2.f Peak sequential and random read/write performance in a small region.
Link speed switching TP2.g Fixed and dynamic link-speed switching under sustained reads.
Model loading TP2.h Read synthetic images of different sizes at various queue counts and queue depths.

Product Radar

Product Radar

This chart shows five aspects of the tested sample. Protocol covers functions related to NVMe and PCIe specifications; performance covers read and write capability; latency concerns response time; power covers electricity consumption; and other includes stress, power cycling and recovery. Each dimension is scored from 1 to 5, with a higher score farther from the center. Power is scored 3: after a group of tests, power stayed elevated throughout measurement when a low-power state was requested.

Performance Positioning

Performance Positioning

Each black dot places one drive according to two tests. Farther right means higher sequential write speed; higher up means stronger random read performance. The width and height of the rectangle represent longer response times in two workloads. Color represents power consumption during testing: blue is lower and red is higher.

Model Loading Time

This test simulates reading model images from an SSD and compares loading times at different queue counts and queue depths.

Model Loading Time

The four panels show small (4.7 GiB) and large (40 GiB) model images, each with a single queue and multiple queues. Queue depth on the horizontal axis is the number of read requests that each queue can issue at the same time; the vertical axis shows average read time. A lower line means the read completed sooner under those test conditions. Each point summarizes multiple measurements; the vertical bars show the observed range.

Key Issues

ID Test ID Description
G70-01 TP2.b After several read/write tests, PS4 was requested and power measured approximately 902–1,008 mW continuously, versus 4.3 mW before testing. Actual power state was not confirmed at every point.
G70-02 TP1.h After invalid PRP injection, eight cases timed out waiting for completion, followed by ten readiness timeouts during initialization. Later tests continued; the cause is unknown.
G70-03 TP2.c The planned six-hour stress test ended after three cycles when a readback verification warning occurred in a deallocated region. Final full-drive verification was not performed; persistent data corruption was not confirmed.
G70-04 TP2.g Thirty negotiation timeouts were recorded while dynamically switching link speed under sustained reads. Gen4 was restored after the test; the cause is unknown.